Protege EliteSuite Eclipse Manuel d'installation Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
,2, 4, [toggle opons], Panic Alarm opons
Opon Descripon Default
1 Enable [1] + [3] Panic alarm Disabled
2 Enable [4] + [6] Medical alarm Disabled
3 Enable [7] + [9] Fire alarm Disabled
4 Enable Duress code Disabled
5-8 Reserved Disabled
,3, [select zone], Select Zone
[select zone type], Select Zone Type
Type Descripon
1 Disabled
2 Delay - Zone has an entry delay
3 Follow - Instant but not if another Zone has already
triggered the entry delay
4 Instant - Zone will trigger instantly
5 24hr - Zone will always cause an alarm immediately
6 Fire - Zone will trigger a Fire alarm instantly
7 Fire delay - Zone will trigger a Fire alarm aer 30s delay
8 Reserved
[select zone opon], Select Zone Opon
Opon Descripon
1 Bypass allowed
2 Stay Zone enable
3 Force Zone enable
4-8 Reserved
43
Vue de la page 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 55 56